Vinegar cannot be eaten with anything

Vinegar taboo, not with the lamb, milk powder with food; avoid gecko, can be fatal.

Vinegar and Milk: Vinegar contains acetic acid and various organic acids. Milk is a colloidal mixture with amphiphilic properties and it has a certain degree of acidity. When the acidity increases to the isoelectric point of 4.6 or less, coagulation and precipitation occur, and it is difficult to be digested and absorbed. People with stomach chills are more likely to cause indigestion or diarrhea. Therefore, ancient talents have the opposite of milk and acid. Therefore, drinking milk or milk powder, it is not advisable to eat vinegar food immediately.

Vinegar and lamb: lamb hot, vinegar sweet, similar to wine, so the two things with food, easy to fire and blood. The mutton soup should not be added vinegar, usually poor heart function and blood disease patients should pay attention. Because lamb is hot, the function of Qi tonic; vinegar contains protein, sugar, vitamins, acetic acid and a variety of organic acids, their acid temperature, swelling and blood circulation, should be combined with cold food, and lamb should not be.

Vinegar and carrots: fried carrots should not be added vinegar. Because carrots contain a lot of carotenoids, they become vitamin A when taken into the body. Vitamin A can maintain eye and skin health. People with rough skin and night blindness are deficient in vitamin A, so don't fry it with vinegar. Carotene was completely destroyed because of the vinegar.

Vinegar and sea cucumber: vinegar acid temperature, sweet and salty sea cucumber, warm, sexually transmitted diseases without return. Sea cucumber is a kind of collagen protein in terms of its composition and structure. It forms a complex spatial structure of collagen fibers. When the external environment changes (such as acid or alkali), it affects the amphiphilic molecules of the protein and destroys its air structure. The nature of the protein changes. If vinegar is used to prepare sea cucumbers, the pH in the soup will decrease, and the protein's spatial structure will change when it is close to the isoelectric point of collagen (pH 4.6). Protein molecules will appear to varying degrees. Agglutination, contraction. At this time, the sea cucumber tasted so delicious that it tasted bad.

Vinegar avoid Salvia miltiorrhiza: Poisoning

Vinegar bogey pumpkin: not good for health

Vinegar bogey pork soup: it will affect the absorption of nutrients

Vinegar and green vegetables: will greatly reduce its nutritional value.

Patient Monitor

Features
10.1 inch high resolution color TFT display
Lightweight and portable design suitable for Ambulance,Emergency Transport
Three Working Modes : Monitoring , Surgery and Diagnosis.
Simple and friendly operating display interface.
Multi-display modes suitable for different applications: Standard Interface , Large font , ECG Standard Full Display ,OXY, Trend able BP Trend.
Built-in high capacity battery up to 3 hours of continuous work


Technique Specification
ECG

Lead Mode : 5 Leads ( I , ll , Ill , AVR , AVL , AVF , V )
Gain : 2.5mm / mV, 5.0mm /mV , 10mm /Mv, 20mm /mV
Heart Rate : 15-300 BPM ( Adult ) ; 15-350 BPM ( Neonatal )
Resolution : 1 BPM
Accuracy : ± 1%
Sensitivity > 200 uV ( Peak to peak )
ST measurement range : -2.0 ~+ 2.0 Mv
Accuracy : -0. 8mV~+ 0. 8mV : ± 0. 02mV or ± 10% , which is greater
Other Range : unspecified
Sweep speed : 12.5 mm / s , 25mm / s , 50mm / s
Bandwidth:
Diagnostic : 0.05~130 Hz
Monitor : 0.5~40 Hz
Surgery : 1~20 Hz

SPO2
Measuring Range : 0 ~ 100%
Resolution : 1%
Accuracy : 70%~100% ( ± 2 % )
Pulse Rate : 20-250 BPM
Resolution : 1 BPM
Accuracy : ± 3 BPM

Optinal Parameters :
Central monitoring system
Dual IBP
Etco 2
12-lead ECG
Nellcor SpO2
Sun Tech NIBP

NIBP
Method : Oscillometry
Measure mode Manual, Auto, STAT
Unit : mmHg , kPa
Measure and alarm range:
Adult Mode
SYS 40 ~ 280 mmHg
DIA 10 ~ 225 mmHg
MEAN 20 ~ 240 mmHg

Pediatric Mode
SYS 40 ~ 220 mmHg
DIA 10 ~ 160 mmHg
MEAN 20 ~ 170 mmHg

Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution : 1 mmHg
Accuracy : ± 5 mmHg

TEMP
Measure and Alarm Range : 0 ~ 50 C
Resolution : 0 . 1C
Accuracy : ± 0 . 1C

Standard Parameters
ECG, RESP, TEMP, NIBP, SPO2, PR

RESP
Method : Impedance between RA-LL or RALA
Measurement Range:
Adult : 10~120 BrPM
Neonatal / Pediatric : 7~150 BrPM
Resolution : 1 BrPM
Accuracy : ± 2 BrPM

Standard Configuration
No Item Qty

  1. 1 Main Unit 1
  2. 2 5-lead ECG cable 1
  3. 3 Disposable ECG Electrode 5
  4. 4 Adult Spo2 probe 1
  5. 5 Adult NIBP cuff 1
  6. 6 NIBP extension tube 1
  7. 7 Temperature probe 1
  8. 8 Power Cable 1
  9. 9 User Manual 1
  10. 10 Fuse 3