Blister cartoning machine, these equipment problems should be noted

The increasing variety and number of drugs and the continuous enrichment of pharmaceutical dosage forms have prompted the improvement of the quality of pharmaceutical packaging materials and the processing and manufacturing of pharmaceuticals in China. With the continuous improvement of the quality of the major pharmaceutical companies, the requirements for pharmaceutical packaging are also increasing, especially the requirements for blister cartoning machines are also increasing.

At present, various multifunctional blister cartoning machines have been applied to various pharmaceutical companies, and the blister carton production line has become a good assistant for many enterprises. Some equipment experts believe that the key to the limited production speed of the blister-packing production line lies in the cartoning machine, and the bottleneck of the cartoning machine lies in the folding machine. Germany has done a better job in this regard.

In addition, the author also learned that the current high-end blister box production line market is mainly occupied by several European packaging companies. Although the equipment of domestic related manufacturers is not advanced by foreign manufacturers, it has technical performance, stability performance and appearance quality. Great progress. However, the problems associated with blister cartoners cannot be ignored.

For example, if a pharmaceutical company has a limited production area reserved for the production plant, the equipment layout is very compact, and the product cache space between adjacent equipment is slightly insufficient, resulting in a certain type of intermittent blister cartoning machine being put into use. Among them, there are often problems when the blister sheet is fed to the lower layer feeding conveyor belt and the lower layer feeding.

Professionals have analyzed this phenomenon: the blister board will be divided into upper and lower layers before entering the cartoning machine. The correct conveying method should be that the short side of the blister board is consistent with the conveying direction. However, in the production process, when the lower blister sheet is pushed into the conveyor belt, the rotation occurs under the friction of the conveyor belt, and the long side of the blister sheet becomes the same as the running direction of the conveyor belt, resulting in the feeding action. failure.

In response to this failure, the professional put forward a suggestion: the three conveyor belts can be re-adjusted in an overlapping manner, so that the three conveyor belts are kept at the same height when overlapping. In the actual adjustment, the overlapping conveyor belts are slightly higher than the two feeding conveyor belts. After adjustment, the cartoning machine can ensure that the blister plate is pushed into the front and rear feeding conveyor belt in a horizontal form by the feeding servo motor, and the blister plate can also be normally transported under the feeding servo motor.

In addition to the problems of the equipment itself, pharmaceutical companies should also pay attention to equipment requirements when carrying out equipment operations. The blister cartoning machine belongs to the inner packaging equipment. According to the GMP requirements, it needs to be placed in the D-class clean level area; and the cartoning machine is an outsourcing equipment, which should be placed in the control.

According to GMP requirements for internal packaging equipment, blister packaging equipment companies need to pay attention to: First, production equipment must not have any adverse impact on the quality of the drug. The surface of the production equipment in direct contact with the drug shall be smooth, smooth, easy to clean or disinfect, and resistant to corrosion. It shall not chemically react with the drug, adsorb the drug or release the substance into the drug.

Second, the lubricants, coolants, etc. used in the equipment must not cause pollution to the medicines or containers. Lubricants of comparable food grade or grade should be used whenever possible. Third, the design, selection, installation, modification and maintenance of the equipment must be in accordance with the intended use. The risk of production pollution, cross-contamination, confusion and errors should be minimized, and it is easy to operate, clean, maintain and disinfect as necessary. .

It should be reminded that the inner packaging equipment and the outer packaging equipment are connected by a conveyor belt or other means, but the conveyor belt cannot pass through different clean level areas to prevent pollution to the relatively clean area. Therefore, blister-packing equipment enterprises should design blister-packing equipment that meets customer needs based on relevant standards, requirements, and market demands, using modern design methods.

main feature 

1.ZF series of reflective shadowless lamp is widely used in various occasions operation lighting needs, is the ideal lighting equipment of modern operation room.

2. Full close streamline lamp body design completely meets the demand of the sterilization and high standard of laminar flow purification in operation room.

3. Adopting more than 5280 slices of reflection mirror, guaranteeing 1200 mm lighting depth.

4. Special design of color temperature compensation provides closer to that of natural sunlight and helps the doctor to distribute operation parts clearly and accurately.

5. The back-up battery will start work within 0.2 seconds automatically in case the main battery is damaged,ensuring the continuation of surgical operation. There`s failure indication in the handle control panel, to recommend the bulb to be changed after operation.

6. detachable handle jacket ,can be used for high temperature (≤134℃)sterilized.

7. Digital-control circuit offers many functions, with 10 segment brightness selection  stepless lighting regulation, brightness memory, low voltage

start-up and power on self test etc.

8. The life-span of OSRAM halogen bulb is up to 1500 hours; the bulbs can be changed easily.

9. Germany ORSAM  lamp socket,thermostability

10.Balance arm can be optional Germany imported or domestic.

11. mould Die-casting  Eight edge type Revolving arm.


18

IMG_2877

Double Dome Halogen Operating Light

Double Dome Halogen Operating Light,Double Dome Halogen Operating Light,LED Halogen Light,Double Dome Halogen Operating Lamp,Double Dome Operating Lamp